<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-12 00-09-42
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 68 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 2.7 kHz -83 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 64 kHz 18979 0,0053
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,4 dBr 5,80 dBr 6,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 64 kHz MIN: 8 kHz % above 76 kHz: 0,0053 Acquired: 2024/12/12 0.08.38 Total samples: 18979 Equivalent time: 0:15:48 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000 6000
FM Scope MAX: 6,5 dBr MIN: 4,4 dBr AVE: 5,80 dBr % above 12,2 dBr: 0,0 Last value: 5,6 dBr (2024/12/12 0.08.38) 23.54 23.56 23.58 00.00 00.02 00.04 00.06 00.08 0 50 100 Dev. MAX [kHz] 0 2 4 6 Pm [dBr]